Attachmate Worldwide  |   Contact Us  |   NetIQ.com
Home » Support » Solution Library

Technical Support

SCO-ANSI Terminal type missing from Designer Studio


Technical Note USA11955
Created 13-Sep-2005

Applies To
Synapta Services Builder for VT 3.0

Synapta Services Builder for VT 2.2


SCO-ANSI

VT52

ANSI-BBS

Symptoms

SCO-ANSI Terminal type missing from Designer Studio

Host screen displays incorrectly in Designer Studio

Missing Terminal types

Host screen displays correctly using EXTRA! X-treme 8 using SCO-ANSI terminal type

Cause

The Terminal types--SCO ANSI, ANSI-BBS and VT52--were removed from Designer Studio in Screen Connectors v2.2.  

Fix

To enable the Terminal types SCO-ANSI, ANSI-BBS and VT52 in Designer Studio:

1.  Apply the CTD 9 for Synapta Services Builder v3.0. (See CTD Readme.txt file for instructions on applying.  Contact AttachmateWRQ Technical Support for information on how to get CTD 9.)

2.  Edit the \EAI\ScreenConnectors\screen.properties file and add this line:

enable.all.vt.terminal.modes=true

This option is currently disabled by default.  

3. In Designer Studio, load your project and select Host, Display Settings from the menu.  All the Terminal types are now available--including SCO-ANSI, VT52 and ANSI-BBS.  After selecting SCO-ANSI (or ANSI-BBS or VT52) as the Terminal type you will now be able to save your project and restart it and the selected Terminal type will stay enabled.  

SCO-ANSI host screens displays correctly and the project can be saved and reopened and the SCO-ANSI terminal type is retained.