Global Startup Macro doesn't start when launching Accessory Manager - reports it can't find Startup.adp file


Technical Note IRE2465
Created 21-Jul-2004

Applies To
INFOConnect for UMC 7.5a

INFOConnect UTS (PEP) with OTS 7.5a

INFOConnect InterCom with OTS 7.5a

Symptoms

Global Startup Macro doesn't start when launching Accessory Manager - reports it can't find Startup.adp file

Changes

INFOConnect2001 has a STARTUP.ADP in ..\Program Files\Attachmate\INFOCN32\Accmgr32\TEMPLATE directory
when a startup macro is used this STARTUP.ADP fake template is opened (as a fake template it doesn't require a path) in minimized form, macro runs and after it's finished the fake session is closed
*
INFOConnect Enterprise 7.5a (INFOConnect Enterprise 7.5) doesn't have the TEMPLATE directory nor STARTUP.ADP template. When one is copied from INFOConnect2001 and placed in  newly created directory ..\Program Files\Attachmate\INFOCNEE\TEMPLATE it starts well but comes up fully initialized and requires a path. After the macro's finished the session cannot be closed.

Fix

Resolved, fix on \\devproduct\TD_ETD:  INFOConnect\_rupert\8005614
fix built for INFOConnect for UMC 7.5a
fix for INFOConnect for UMC 7.5 (base release) not built